Installation
:
The ED2- SLL Series SkidWeigh can be installed and calibrated
by a local forklift dealer technician or end user forklift mechanic.
The system is calibrated with known weights with a normal load center
of 24" on the forks, raised 3" to 4" of the ground.
Technical
Data :
Electrical
Voltage: 24 to 48 V DC
Current: Operating 60mA
Environmental :
Operating temperature -25 ºC to + 70 ºC
Water and dust resistant
Triple shock mounting bracket included
Physical :
120 x 80 x 55 mm , polycarbonate enclosure
Technology :
Micro Controller
Pressure Transducer
Standard pressure port connection: G 1/4 , male thread standard
Pressure transducer adapter G1/4 to 1/4"-18 NPT male included in
kit
Optional pressure port : M 12x 1,5
Accuracy: +/- 0.3% of full scale
Repeatability: +/- 0.05% of full scale
Hysteresis: +/- 0.1% of full scale
Stability: +/- 0.2% full scale/yr
Temperature Information :
Compensation: 32° F to 175° F
Drift: +/- 0.03% /50 ° F
Medium: -22° F to 212° F
Ambient: 14° F to 175° F
Storage: -40° F to 212° F
Materials of Construction :
Casing: Stainless steel 1.4305 (AISI 303)
Weight :
95 grams
Shock Sensitivity :
<+/- 0.05% full scale @ 100g for 20 ms
Vibration Sensitivity :
<+/- 0.05% full scale @ 35g & 5-2000Hz
Response Time : < 0.1 ms, 10-90%
FS
Frequency Limit : 150 Hz
Proof Pressure, 2,5 x range
Burst Pressure, 2,5 x range
Output, 3 wires 0 - 2,5 V DC
Protection :
Environmental: IP67
Fault :
Reverse polarity
Over voltage
Short circuit
Swiss Made Pressure Sensors
Standard
outside thread G 1/4 male, sealed at back DIN3852/E with pressure tip
orifice
| Interference
Stability |
Test
Standard |
Effects |
| Electrostatic discharge (ESD) |
EN 61000-4-2
15 kV air discharge, 6kV contact discharge |
No effect |
| High- frequency electromagnetic radiation (HF) |
EN 61000-4-6
200mV, 80....1000Mz |
No effect |
| Conducted HF interferences |
EN 61000-4-6
30V. 0,15...80 Mhz |
No effect |
| Fast transients (burst) |
EN 61000-4-4
4kV |
No effect |
| Surge |
EN-6100-4-5
Line-Line, Line-Case 500V, 12Ohm, 9µF |
No failure |
| Magnetic fields |
EN 6100-4-8
30A/m, 50 Hz |
No effects |
| Insulation voltage |
500 V DC ( optional 1000 V DC ) |
No effect |
| Interference emit |
Test standard |
Effects |
| Conducted interference Radiation from housing |
EN 55022
0,15... 30Mhz
30... 1000Mhz, 10 meters |
No emission

|
System Check Weighing Accuracy
:
+/- 0.5% to 1% of forklift lifting capacity
Display :
Six digits LED
Order Number :
ED2-SLL-SkidWeigh
Download
Installation Instructions for ED2 Series pdf file


Integrated Visual Data Technology