The LFC Series SkidWeigh Plus System is an electronic device that can be installed on any large capacity lift truck in order to convert it into a mobile check weighing scale. 

When the operator activates the "W" key and the load is picked up, the hydraulic pressure on the lift truck is automatically activated and converted to a weight measurement and presented to the operator visually via an LCD display, 2 lines x 16 characters.

In addition to it’s check weighing capability, the system allows the operator to enter the Waybill ID#, accumulate load weights under designated Waybill ID#’s, enter tare value into the system and obtain printout tickets if the on-board printer is connected to the monitor.

The system check weighing readout is limited to the lifting capacity of the material handling vehicle. 

For example, over 10,000 lbs. - 100,000 lbs.

 

Electronic Digital LCD Display System
Large Forklift On-board Weight Verification

 

   

Lift-O-Graph ECCR-125 Series

Material Handling Vehicle Lift Activity Data Recorder in % of Vehicle Lifting Capacity

 

 

Indicator Mounting - Nissan 60 - Closeup.jpg (30755 bytes)  Hyd Pressure Transducer Installation - Nissan 60 - CloseupLeft.jpg (41589 bytes)  Hyd Pressure Transducer Installation - Nissan 60.jpg (46497 bytes)
 
wpe84566.gif (188281 bytes)  Indicator Mounting - Nissan 60 - Oper Cell.jpg (34304 bytes)
click image to enlarge it


  APPLICATION

  • Container Lifters
  • Loaders
  • Diesel Fork Lift Trucks
  • LPG Fork Lift Trucks
  • High Rack Stacker
  • Multi-Way Reach Trucks
  • Electric Four-Wheel Trucks
  • Electric Three-Wheel Trucks
  • Electric Pallet Truck/Stacker
  • Electric Sideways Seat Stacker
  • Electric Pedestrian Stacker

      
    SP-1000 Series.pdf

SKIDWEIGH PLUS REPORTS

Load Weight Printout Ticket :
Date:                         95/02/24
Time:                        11:34
Oper.ID:                   12011
Vehicle #:                 102
Dept.#:                      12
Way #:                       17889
# of WRT:                  4
Tot. Weight:             12015 lb

Technical Data :

Electrical : - Voltage: 12 to 55 V DC

Monitor Display :
- 2 lines x 16 characters LCD (supertwist)
- LED backlight
- Large character size (4.84 x 8.06 mm)
- Temperature range 0 ºC to 50 ºC

Environmental :
Operating temperature
- (-10 ºC to +50 ºC)
- Humidity up to 90%, no condensation

Enclosure :
- Water and dust resistant
- Machined aluminum
- Universal mounting bracket

Physical :
- Length: 242 mm
- Width: 151 mm
- Depth: 44 mm
- Weight: 1100 g

Alphanumeric Keyboard :
- Enlarged 16 key with tactile feedback
- Audible key signal during data entry
- Sealed keyboard, watertight
- Functions overlay

Status Indicators :
- System On
- Overload
- Lift 2
- Lift1
- Motion
- Transmitting

Scrolling Features :
- Allows overall status and session statistics to be displayed


Automatic Time-Out Function :
- Automatic recovery to user mode after 7 seconds if operator does not complete input  instructions

Real Time Clock :
- Continuous operation
- Hours / Minutes
- Year / Month / Day

Eprom :
- Up to 64 K bytes for application programs

Ram :
- Up to 128 K bytes for program and data storage

CPU :
- Intel 8032

Monitor Interface :
- Serial interface for printer
- Serial interface for IR, RF or link to PC

Communication :
- Automatic download of finished sessions
- Up to 9600 baud ( asynchronous )

Monitor calibration :
- External calibration via keypad with clear LCD instructions in English ( No codes )

Calibration Security :
- Only a secure ID# to initiate the calibration mode


Swiss Made Pressure Sensors

Standard outside thread G 1/4 male, sealed at back DIN3852/E with pressure tip orifice 

Interference Stability Test Standard Effects
Electrostatic discharge (ESD) EN 61000-4-2                         15 kV air discharge, 6kV contact discharge No effect
High- frequency electromagnetic radiation (HF) EN 61000-4-6                 200mV, 80....1000Mz No effect
Conducted HF interferences EN 61000-4-6                      30V. 0,15...80 Mhz No effect
Fast transients (burst) EN 61000-4-4                       4kV No effect
Surge EN-6100-4-5                 Line-Line, Line-Case 500V, 12Ohm, 9µF No failure
Magnetic fields EN 6100-4-8                     30A/m, 50 Hz No effects
Insulation voltage 500 V DC ( optional 1000 V DC )  No effect
Interference emit Test standard Effects
Conducted interference Radiation from housing EN 55022                        0,15...   30Mhz                    30... 1000Mhz, 10 meters No emission

Pressure Transducer
Standard pressure port connection: G 1/4 , male thread standard
Pressure transducer adapter G1/4 to 1/4"-18 NPT male included in kit
Optional pressure port : M 12x 1,5 
Accuracy: +/- 0.3% of full scale
Repeatability: +/- 0.05% of full scale
Hysteresis: +/- 0.1% of full scale
Stability: +/- 0.2% full scale/yr

Temperature Information :
Compensation: 32° F to 175° F
Drift: +/- 0.03% /50 ° F
Medium: -22° F to 212° F
Ambient: 14° F to 175° F
Storage: -40° F to 212° F

Materials of Construction :
Casing: Stainless steel 1.4305 (AISI 303)

Weight :
95 grams

Shock Sensitivity :
<+/- 0.05% full scale @ 100g for 20 ms

Vibration Sensitivity :
<+/- 0.05% full scale @ 35g & 5-2000Hz

Response Time : < 0.1 ms, 10-90% FS

Frequency Limit : 150 Hz

Proof Pressure, 2,5  x range

Burst Pressure, 2,5  x range

Output, 3 wires 0 - 2,5 V DC

Protection :
Environmental:  IP67

Fault :
Reverse polarity
Over voltage
Short circuit

Order Guide:

SP-1000 - LFC         Standard Unit

SP-1000 - LFC - 10  Standard Unit with 12V DC Printer

SP-1000 - LFC - 20  Standard Unit with 24-48V DC Printer 

SkidWeigh Plus Calibration Procedure



Patented Technology USA 4,757,712; 4,949,263 Canada 1302566; 1304479 Australia 598,376; 605,647 Germany 38811280.0; 3887754.6 EC 0293697; 0351453

 